Competitor Search
click here to chat with us
RGA400-10 DC Motor Control

RGA400-10 DC Motor Control

RGA Series

The RGA series of 4Q drives is well suited for applications that require the control of overhauling loads, frequent reversing or breaking. With on-board fusing and cage clamp power and logic terminals, installation has been made simple. Available in either open chassis style or in a NEMA 4X enclosure, the RGA series can be used in a wide range of environments. With the available field supply for shunt-wound motors, full assortment of adjustments that are standard on all our 4Q drives, and optional factory installed isolation module, the RGA series is a flexible and well equipped member of our 4Q family of drives.


Potentiometer Kit 202-0003 is included with a purchase of the RGA400-10

$621.66

Contact the factory for volume pricing

Model
Number
Enclosure Maximum
Current
(ADC)
Input
Voltage
(VAC)
Output
Voltage
(VDC)
Power Range Field / Shunt
Supply
Braking Reversing Isolation
HP kW
RGA400-10 Chassis 10* 115 0 - 90 1/8 - 1 .09 - .75 50 / 100 Yes
(Regenerative)
Yes
(Regenerative)
No
230 0 - 90 1/8 - 1 .09 - .75 100 / 200
0 - 180 1/4 - 2 .19 - 1.5

* Heat sink kit 223-0235 must be used when the continuous output current is above 7 amps.

Features

  • 4Q Reversing: Regenerative / 4-Quadrant drives have the ability to perform quick and contactorless braking and/or reversing-on-the-fly
  • Field Supply Voltage output to energize the field winding of a shunt-wound motor
  • Stopping Modes: Inhibit (N.O.) for braking to a stop. Enable for coasting to a stop. Can be used for rapid starting and stopping
  • Tach Feedback: Accepts tachogenerator feedback for tighter speed regulation
  • On-board Fusing Drives include on-board fusing

Technical Data

  • 1.37 Form Factor
  • 1% Base Speed Regulation over 50:1 Speed Range
  • 0.1% Base Speed Regulation over 60:1 Speed Range with Tach

Trim Pots

  • Maximum Speed
  • Minimum Speed
  • Forward Acceleration
  • Reverse Acceleration
  • Forward Current Limit
  • Reverse Current Limit
  • IR Compensation
  • Deadband
  • Tach